MDCB Credits: 2.50
ARRT Credits: 1.00
Available Until: 7/31/2028
Non-Member Price: $87.50
Member Price: $50.00
Member PLUS Price: $50.00
Once you have exceeded your annual free credit allowance you will be prompted to pay a per-credit fee.
Courses purchased using your credit allowance are non-refundable and need to be completed before their expiration date
View your annual credit allowance here.
Authors: Priyanka Agarwal, MSc, DRP ∗,†,1, Biplab Sarkar, PhD†,‡, Monika Goyal, PhD†, Ryan Clark, MS, CMD §, Anthony Magliari, MS, CMD §, Luca Cozzi, PhD?,¶
∗ Medical Affairs, Varian Medical Systems, New Delhi, India
† Department of Physics, GLA University, Mathura, Uttar Pradesh, India
‡ Department of Radiation Oncology, Apollo Multispecialty Hospital, Kolkata, West Bengal, India
§ Medical Affairs, Varian Medical Systems, Palo Alto, USA
? Medical Affairs, Varian Medical Systems Italy, Milan, Italy
¶ Radiotherapy and Radiosurgery Department, Humanitas Research Hospital IRCCS, Milano-Rozzano, Italy
RapidArc Dynamic is an advanced evolution of arc-based radiotherapy that extends the principles of VMAT with real-time modulation of gantry speed, dose rate, and dynamic collimator within a single treatment arc. The aim of this study is to investigate how the dynamic collimator rotation and gantry pausing in?uence treatment quality - results relative to 3DCRT with Field-in-Field (3DCRT-FiF), IMRT, and VMAT planning approaches within the FAST-Forward framework. A retrospective study was conducted on 30 previously treated patients with early-stage breast cancer. Each patient was replanned using four techniques: 3DCRT-FiF, IMRT, VMAT, and RapidArc Dynamic (RAD), generating a total of 120 treatment plans. The prescribed dose was 26.0 Gy in 5 fractions, generated on TrueBeam linear accelerator using Eclipse TPS (v18.1). Treatment Planning was assessed using DVH metrics for PTV and OARs for dose analysis. All techniques achieved acceptable PTV coverage, normalized with V95 % = 95 % of the target volume. 3DCRT-FiF achieved robust coverage but resulted in higher OAR doses. IMRT improved homogeneity but obtained higher monitor units. VMAT offered improved conformity and OARs sparing but demonstrated a larger low-dose bath. RAD achieved the most favorable balance, with superior conformity, reduced OARs doses, minimized low-dose exposure, and reduced treatment delivery time. The mean body dose was observed to be 2.67 Gy, 2.15 Gy, 2.56 Gy, and 2.13 Gy for 3DCRT-FiF, IMRT, VMAT, and RAD, respectively. The total optimization and dose calculation time for RAD were observed to be approximately less than 5.0 min. RapidArc Dynamic approach provides superior dosimetric advantages over conventional techniques for FAST-Forward regimens in breast patients.
As of January 1, 2022, ARRT requires CE Credits for Directed Journal Readings to be based on the word count for each article. So, the number of CE Credits for each DJR article will vary for ARRT.
ARRT CQR Credit Distribution
Radiation Therapy 2022:
Procedures
Prescription and Dose Calculation = 1.0
Radiation Therapy 2027
Procedures
Prescription and Dose Calculation = 1.0